I. General Description
MD-F1 Hook load protection device is an electronic indicating instrument with stable structure to monitor the pressure changes of indicator hydraulic system.
II. Brief Principle
A microprocessor is installed in the host, the hook load sensor is installed in the system hydraulic pipeline, it will be proportional to the cylinder hydraulic current signal to the host, and then in the host the analog-digital conversion circuit will be transferred to the digital signal to the processor, through digital processing technology to calculate the hook lifting load, compare the actual load and pre-set alarm limits, to achieve large Overload protection for hook loads
Ⅲ.Technical Parameters and Accuracy
Operation temperature -45℃-70℃
Power supply 24VDC 2A
Main host 251mm×192mm×85mm
Display accuracy ±0.2%
OFF/ON/ Setting switch Rotary switch
Button Momentary connection
System weight About 6KG
Load display range 0~2000KN
Relative humidity 35~85% RH
Explosive-proof class Ex-proof dIIBT4
Protection class IP65
Ability to resist noise and interference 1000Vp-p, pulse width 1 micro, frequency 30-100HZ
Ⅳ.Product Photo